Condensing gas furnace, up-flow (coil above furnace)
What the notices say. Any furnace brand, with coil serial numbers starting 1901 through 2101, installed or repaired with a new drain pan from January 2019 through November 2021.
Goodman recalled about 298,300 evaporator coil drain pans installed with condensing gas furnaces in an up-flow configuration on November 18, 2021, plus about 44,000 in Canada; Daikin Comfort Technologies, formerly Goodman, expanded the recall on July 28, 2022 to drain pans installed with some competitor-brand non-condensing furnaces. The notices say the molded plastic drain pan at the bottom of the evaporator coil can overheat, melt and deform, a fire hazard; the 2022 notice counts 26 fires with significant fire and smoke damage to homes and no injuries. A qualified technician repairs affected systems free.
Search recall notices since 2016. Search every CPSC and Health Canada notice since 2016 by brand or product name.
The evaporator coil sits on top of the furnace. Its serial number is on a label on the coil case (cased coils) or on the front of the coil (uncased coils). The furnace brand and model are usually on the Energy Guide label, and the outdoor condenser model is on a label on the condenser. The model verification tool at recallrtr.com/drainpan walks through the check.
| System | What the notices say | Notice |
|---|---|---|
| Condensing gas furnace, up-flow (coil above furnace) | Any furnace brand, with coil serial numbers starting 1901 through 2101, installed or repaired with a new drain pan from January 2019 through November 2021. | |
| Non-condensing gas furnace, up-flow, certain configurations | Competitor brands only (not Goodman, Daikin or Amana), coil serial numbers starting 1901 through 2101, January 2019 through November 2021; whether it is included depends on where the burners are. |
What the notices say. Any furnace brand, with coil serial numbers starting 1901 through 2101, installed or repaired with a new drain pan from January 2019 through November 2021.
What the notices say. Competitor brands only (not Goodman, Daikin or Amana), coil serial numbers starting 1901 through 2101, January 2019 through November 2021; whether it is included depends on where the burners are.
Sold through independent heating and cooling equipment dealers from January 2019 through November 2021 for 200 to 1,200 US dollars per drain pan and coil, sometimes bundled with a furnace and installation. Health Canada gives about 44,000 installed or sold in Canada and says the drain pans were made in the USA.
These are the steps the notices give.
Use the model verification tool at recallrtr.com/drainpan, which asks for the coil serial number, the furnace brand and model and the outdoor condenser model.
Contact Daikin Comfort Technologies (Goodman) to register for a free repair by a qualified technician, at 888-520-0579, 7 a.m. to 6 p.m. CT on weekdays, or goodmanmfg.com (PRODUCT RECALL).
Evaporator coil drain pans with coil serial numbers starting 1901 through 2101, installed from January 2019 through November 2021 in an up-flow configuration with condensing gas furnaces, and with certain competitor-brand non-condensing furnaces.
Use the model verification tool at recallrtr.com/drainpan or call 888-520-0579; the company can help gather the serial and model numbers.
No injuries are reported, but the 2022 notice gives 26 fires.
The two CPSC notices and the two Health Canada notices for the drain pans, with how to check and the repair.
The CPSC notice, recall number 22-021, covers about 298,300 evaporator coil drain pans paired with residential condensing gas furnaces in an up-flow configuration, installed or repaired with a new drain pan from January 2019 through November 2021, with coil serial number prefixes 1901 through 2101, plus about 44,000 in Canada. Independent heating and cooling equipment dealers sold them for 200 to 1,200 US dollars per unit. Goodman received 23 reports of fire, with significant fire and smoke damage to homes and no injuries. The maker is Goodman Manufacturing of Houston, Texas.
The coil serial number is on a label on the coil case or the front of the coil; the furnace brand and model are on the Energy Guide label.
Contact Goodman to register for the free repair, using the model verification tool at recallrtr.com/drainpan. Goodman is at 888-520-0579, 7 a.m. to 6 p.m. CT on weekdays.
The CPSC notice, recall number 22-193, expands the November 2021 recall to drain pans installed with certain competitor-brand (not Goodman, Daikin or Amana) non-condensing gas furnaces in an up-flow configuration, with the same serial prefixes and dates, about 298,300 units plus about 44,000 in Canada. Daikin Comfort Technologies has received 26 reports of fire, including three since November 2021, and no injuries. The maker is Daikin Comfort Technologies Manufacturing, formerly Goodman, of Houston, Texas.
Use the model verification tool at recallrtr.com/drainpan; for non-condensing furnaces it depends on the location of the burners.
Contact Daikin Comfort Technologies to find out whether your unit is included and register for the free repair by a qualified technician; it is contacting registered owners. It is at 888-520-0579, 7 a.m. to 6 p.m. CT on weekdays.
Goodman Recalls Evaporator Coil Drain Pans due to Fire Hazard
The Health Canada notice, RA-63558, covers the same drain pans installed with condensing gas furnaces in an up-flow configuration. It says about 44,000 were installed in Canada and about 298,300 in the United States, from January 2019 through November 2021. As of November 17, 2021, there were no reports in Canada; in the United States, 23 fires and no injuries. They were made in the USA.
Use the model verification tool at recallrtr.com/drainpan.
Use the model verification tool right away and, if the system is included, contact Goodman for a free repair by a qualified technician, at 888-520-0579, 7 a.m. to 6 p.m. CT on weekdays.
The Health Canada notice, RA-64408, expands the recall to certain competitor-brand non-condensing gas furnaces in an up-flow configuration. It gives about 44,000 sold in Canada and about 298,300 in the United States, from January 2019 to November 2021. As of July 28, 2022, there were no reports in Canada; in the United States, 26 fires, three after the November 2021 recall, and no injuries.
Use the model verification tool at recallrtr.com/drainpan.
Use the model verification tool right away and, if the system is included, contact Goodman for a free repair by a qualified technician, at 888-520-0579, 7 a.m. to 6 p.m. CT on weekdays.