The two CPSC notices and the expanded Health Canada notice for Igloo 90-quart rolling coolers, with every model, the date codes and the free handle.
CPSC · 2025-02-13
Igloo Recalls More Than One Million 90 Quart Rolling Coolers Due to Fingertip Amputation and Crushing Hazards
What the notice says
The CPSC notice, recall number 25-136, covers about 1,060,000 Igloo 90 qt Flip & Tow rolling coolers made before January 2024, plus about 47,000 sold in Canada and 23,000 in Mexico. The coolers have a tow handle and IGLOO printed on the side, in many body and lid colors. Costco, Target, Academy, Dick's and other stores, and Amazon.com, Igloocoolers.com and other websites, sold them from January 2019 through January 2025 for between 80 and 140 US dollars. Igloo received 12 reports of fingertip injuries, including amputations, bone fractures and cuts. The maker is Igloo Products Corp. of Katy, Texas, and the coolers were made in the United States.
Models and date codes in the CPSC notice
- 34143 Latitude 90 Roller, 07/2021 to 12/2023
- 27019 MaxCold Latitude 90 Roller Powerade, 11/2020 to 12/2023
- 34202 MaxCold 90 Roller, 07/2021 to 12/2023
- 34241 Latitude 90 Roller MaxCold, 07/2021 to 12/2023
- 34389 Latitude 90 Roller, 08/2021 to 12/2023
- 34424 Latitude 90 Roller, 10/2019 to 12/2023
- 34488 Latitude 90 Roller MaxCold, 03/2019 to 12/2023
- 34506 Latitude 90 Roller, 08/2021 to 12/2023
- 34527 Latitude 90 Roller, 09/2019 to 12/2023
- 34547 Latitude 90 Roller MaxCold, 09/2019 to 12/2023
- 34553 Latitude 90 Roller MaxCold, 09/2019 to 12/2023
- 34577 Latitude 90 Roller, 09/2019 to 12/2023
- 34578 Latitude 90 Roller, 09/2019 to 12/2023
- 34591 Latitude 90 Roller MaxCold, 11/2019 to 12/2023
- 34608 Latitude 90 Roller MaxCold, 12/2019 to 12/2023
- 34619 Latitude 90 Roller, 01/2020 to 12/2023
- 34624 Latitude 90 Roller MaxCold, 01/2020 to 12/2023
- 34689 MaxCold Latitude 90 Roller, 03/2020 to 12/2023
- 34724 MaxCold Latitude 90 Roller, 09/2020 to 12/2023
- 34734 Latitude 90 Roller, 09/2020 to 12/2023
- 34750 Latitude 90 Roller, 09/2020 to 12/2023
- 34752 MaxCold Latitude 90 Roller, 09/2020 to 12/2023
- 34775 Latitude 90 Roller, 09/2020 to 12/2023
- 34776 EcoCool Latitude 90 Roller MaxCold, 10/2020 to 12/2023
- 34789 MaxCold Latitude 90 Roller, 11/2020 to 12/2023
- 34799 Latitude 90 Roller, 12/2020 to 12/2023
- 34800 MaxCold Latitude 90 Roller, 01/2021 to 12/2023
- 34818 MaxCold Latitude 90 Roller, 03/2021 to 12/2023
- 34841 Latitude 90 Roller MaxCold, 05/2021 to 12/2023
- 34844 Sportsman 90 Latitude Roller, 04/2021 to 12/2023
- 34869 Latitude 90 Roller, 06/2022 to 12/2023
- 34993 MaxCold Latitude 90 Roller, 07/2023 to 12/2023
- 34999 Latitude 90 Roller, 08/2023 to 12/2023
- 35003 MaxCold 90 Quart Eco Roller, 06/2023 to 12/2023
- 35019 MaxCold Latitude 90 Roller, 07/2023 to 12/2023
- 35044 MaxCold Latitude 90, 10/2023 to 12/2023
- 35045 MaxCold Latitude 90, 10/2023 to 12/2023
- 35052 Latitude 90 Roller, 10/2023 to 12/2023
- 35053 Latitude 90 Roller, 10/2023 to 12/2023
- 35054 Latitude 90 Roller, 10/2023 to 12/2023
- 35065 Latitude 90 Roller MaxCold, 11/2023 to 12/2023
- 49870 Latitude 90 Roller, 09/2018 to 12/2023
- 49928 Latitude 90 Roller, 08/2019 to 12/2023
- 49937 Latitude 90 Roller, 08/2018 to 12/2023
- 49938 Latitude 90 Roller, 09/2018 to 12/2023
- 50680 MaxCold Latitude 90 Quart, 09/2023 to 12/2023
How to check your model
The model number is on labels on the bottom of the cooler. The date of manufacture is stamped on the bottom in a circle, with an arrow pointing to the month and the last two digits of the year inside. The notice lists 46 models, each with its range of date codes.
What the notice tells owners to do
Stop using the cooler right away and contact Igloo for a free replacement handle, at 888-943-5182, 8 a.m. to 5 p.m. ET on weekdays, igloo90qt@sedgwick.com or igloo90qtrecall.expertinquiry.com.
CPSC · 2025-05-08
Igloo Expands Recall of 90 Qt. Rolling Coolers Due to Fingertip Amputation and Crushing Hazards; Total Recalled Now Nearly 1.2 Million
What the notice says
The CPSC notice, recall number 25-253, adds about 130,000 Igloo 90 qt Flip & Tow rolling coolers made before January 2024 in three more models, plus about 20,000 in Canada and 5,900 in Mexico, bringing the total to nearly 1.2 million. Since the recall was announced in February 2025, Igloo has received 78 reports of fingertip injuries, including 26 with fingertip amputations, bone fractures or cuts. They were sold at the same stores and websites from January 2019 through January 2025 for between 80 and 140 US dollars.
Models and date codes added in May 2025
- 34692 Latitude 90 QT Roller, 07/2020 to 09/2021
- 34785 Latitude 90 QT Roller, 10/2021 to 12/2022
- 34790 MaxCold Latitude 90 QT Roller, 10/2021 to 02/2023
How to check your model
The model number is on labels on the bottom of the cooler, and the date of manufacture is stamped in the circle on the bottom.
What the notice tells owners to do
Stop using the cooler right away and contact Igloo for a free replacement handle, at 888-943-5182, 8 a.m. to 5 p.m. ET on weekdays, igloo90qt@sedgwick.com or igloo90qtrecall.expertinquiry.com.
Health Canada · 2025-02-13
Expanded recall: Igloo 90-Quart Flip & Tow Rolling Coolers recalled due to fingertip amputation and crushing hazards
What the notice says
The Health Canada notice, RA-76946, is a joint recall with the US CPSC and Igloo Products Corp. It was first published on February 13, 2025 and expanded with more models on May 8, 2025. It covers Igloo 90-quart Flip & Tow rolling coolers with a tow handle made before January 2024: about 66,811 sold in Canada, 1,190,301 in the United States and 28,571 in Mexico, from May 2019 to March 2025. As of May 7, 2025, there were 4 reports of minor injuries in Canada; in the United States, 78 reports of fingertip injuries since February 2025, including 26 amputations, fractures or cuts. The coolers were made in the United States.
Models in the Health Canada notice
- 27019 MaxCold Latitude 90 Roller Powerade
- 34143 Latitude 90 Roller
- 34202 MaxCold 90 Roller
- 34241 Latitude 90 Roller MaxCold
- 34389 Latitude 90 Roller
- 34424 Latitude 90 Roller
- 34488 Latitude 90 Roller MaxCold
- 34506 Latitude 90 Roller
- 34527 Latitude 90 Roller
- 34547 Latitude 90 Roller MaxCold
- 34553 Latitude 90 Roller MaxCold
- 34577 Latitude 90 Roller
- 34578 Latitude 90 Roller
- 34591 Latitude 90 Roller MaxCold
- 34608 Latitude 90 Roller MaxCold
- 34619 Latitude 90 Roller
- 34624 Latitude 90 Roller MaxCold
- 34689 MaxCold Latitude 90 Roller
- 34692 Latitude 90 QT Roller (added)
- 34724 MaxCold Latitude 90 Roller
- 34734 Latitude 90 Roller
- 34750 Latitude 90 Roller
- 34752 MaxCold Latitude 90 Roller
- 34775 Latitude 90 Roller
- 34776 EcoCool Latitude 90 Roller MaxCold
- 34785 Latitude 90 QT Roller (added)
- 34789 MaxCold Latitude 90 Roller
- 34790 MaxCold Latitude 90 QT Roller (added)
- 34799 Latitude 90 Roller
- 34800 MaxCold Latitude 90 Roller
- 34818 MaxCold Latitude 90 Roller
- 34841 Latitude 90 Roller MaxCold
- 34844 Sportsman 90 Latitude Roller
- 34869 Latitude 90 Roller
- 34993 MaxCold Latitude 90 Roller
- 34999 Latitude 90 Roller
- 35003 MaxCold 90 Quart Eco Roller
- 35019 MaxCold Latitude 90 Roller
- 35044 MaxCold Latitude 90
- 35045 MaxCold Latitude 90
- 35052 Latitude 90 Roller
- 35053 Latitude 90 Roller
- 35054 Latitude 90 Roller
- 35065 Latitude 90 Roller MaxCold
- 49870 Latitude 90 Roller
- 49928 Latitude 90 Roller
- 49937 Latitude 90 Roller
- 49938 Latitude 90 Roller
- 50680 MaxCold Latitude 90 Quart
How to check your model
The model number is on labels on the side and bottom of the cooler. The date of manufacture is stamped on the bottom in a circle, with an arrow pointing to the month and the last two digits of the year inside. The notice lists 49 models, three of them marked as added.
What the notice tells owners to do
Stop using the cooler right away and contact Igloo for a free replacement handle, at 1-888-943-5182, 8 a.m. to 5 p.m. ET, Monday to Friday, or at igloo90qtrecall.expertinquiry.com.