Lasko space heater recall. Older Lasko notices, from 2004 to 2011, with model numbers and date codes, are on that page.

Is mine affected?

  • Model number. Each notice says where it is printed. DREO, Govee and Vornado put it on a label on the underside or bottom. Merkury has it on a white label on the bottom and on the packaging. Konwin has it on a label on the bottom, and Atomi on a sticker on the bottom. Cadet’s label shows through the bottom of the air outlet grill. DEWALT’s notice names the hang tag. Shop LC’s SKU numbers are not printed on the heater.
  • Date code or manufacture date. The model alone does not settle it for several notices. DREO DR-HSH015 covers units made from 2025/04 to 2026/01. Vornado VH2 covers the date codes JUL24 and AUG24, and the 2023 SRTH notice covers JUL22. Cadet Apex72 lists dates by model, and Danby covers units made in June 2022. The Mastercraft garage heaters use MM-YY or MM/YYYY codes. Read the row, then the notice.
  • What to do. Stop using a unit that a notice includes. Several remedies ask owners to cut the power cord and send a photo: DREO, Merkury, Atomi, Govee, Home Easy and Danby do, and the Sienhua notice tells owners to sever the cord. Read the firm’s steps before you cut anything.

The list

A row is one official notice. Two rows for one brand mean the notices cover different models, dates, or remedies. A Health Canada warning is not a recall: it tells owners to stop using a product, and its row is marked.

BrandModelsDateRemedySource
AtomiAT1323, AT1481, AT1520, AT1632, AT1482, AT1521, AT16352024-07-11Stop using it, unplug it, and register at atomiheaterrecall.com for a full refund. Registration asks for photos of the cut cord and the label.CPSC notice
AtomiAT1514, AT1513, AT16772024-07-11Stop using it and register at atomiheaterrecall.com for a refund. Dispose of the heater under your municipality’s electronic waste rules.Health Canada notice
CadetHW128, HW132, HW151 (made 01-Mar-21 to 29-Feb-24), HW162, HW162BP5, HW168, HW168BP5 (made before 01-Mar-24)2024-09-12Stop using it and contact Glen Dimplex for a free replacement and free installation by a qualified technician.CPSC notice
DanbyDBSH01113WD13, made June 20222023-08-01Stop using it and unplug it. Send Danby a photo of the cut cord for a full refund.Health Canada notice
DEWALTDXH70CFAVX2025-04-03Stop using it and contact Enerco for new start instructions and a warning sticker. The remedy is a repair, not a refund.CPSC notice
DEWALTDXH70CFAVX, F3406662025-04-03Stop using it and contact Enerco for new start instructions and a free warning sticker.Health Canada notice
DREODR-HSH015, made 2025/04 to 2026/012026-10-29Stop using it and contact DREO for a free replacement. DREO asks for a photo of the heater with the cord cut.CPSC notice
DREODR-HSH015, made 2025/04 to 2026/012026-10-29Stop using it and contact DREO for a free replacement heater.Health Canada notice
GoveeH7130, H7130101, H7131, H7132, H7133, H7134, H71352024-11-07Stop using it and use Govee’s recall page for a refund. A full refund needs the order number; without it the refund depends on the model.CPSC notice
GoveeH7130, H7130101, H7131, H7132, H7133, H7134, H71352024-11-07Stop using it and register on Govee’s recall page for a refund.Health Canada notice
Home EasyDH-QN062022-02-09Stop using it and contact Home Easy for a full refund. The refund asks for a photo of the cut cord.CPSC notice
KonwinBHN21332025-03-13Stop using it and return it to any Meijer store for a full refund to the original form of payment.CPSC notice
MastercraftEH-4604BY, Mastercraft, date codes ending in 2020 or 2021, EH-4604BY, Thermosphere, date codes ending in 20202023-05-05Stop using it and return it to the place of purchase for an exchange or a refund.Health Canada notice
MastercraftHA22-48M and HA22-48M1 (Mastercraft, blue, any date), HA22-48M (Profusion Heat, Prestige, Matrix, red, made June 2017 or earlier)2023-08-24Stop using it and return it to the store where you bought it for a store credit or a replacement. No proof of purchase is needed.Health Canada notice
MerkuryMIC-DHC02, as printed in the Health Canada notice2026-04-29Stop using it and return it to any HomeSense, Winners or Marshalls for a refund.Health Canada notice
MerkuryMI-DHC022026-06-11Stop using it and contact Merkury Innovations for a full refund. The refund asks for a photo of the product with the cord cut.CPSC notice
Shop LCSKU 3666115, SKU 3666117, SKU 3666118, SKU 36661192022-02-10Stop using it and return it to Shop LC with the free prepaid label. The refund goes back to the original payment method.CPSC notice
Shop LCSKU 3666115, SKU 3666117, SKU 3666118, SKU 36661192022-06-16Stop using it and return it to Shop LC. The notice gives Shop LC’s toll-free number and email address.Health Canada notice
SimnobleAmazon.ca ASIN B0B7MQQQW92024-11-28Stop using it and dispose of it under your municipality’s electronic waste rules. The notice does not mention a refund.Health Canada warning
VornadoTYPE SRTH with date code JUL222023-03-09Stop using it and register on Vornado’s website for a full refund.CPSC notice
VornadoTYPE VH2 with date code JUL24 or AUG242025-01-16Stop using it and contact Vornado to confirm the unit. Included heaters get a free replacement.CPSC notice
VornadoTYPE SRTH2026-06-04Stop using it and contact Vornado for a full refund. The refund asks for photos and proof that the heater was destroyed.CPSC notice
VornadoTYPE SRTH, Part number EH1-0084-06 (black), Part number EH1-0084-43 (ice white)2026-06-04Stop using it and contact Vornado Air for a refund.Health Canada notice
WarmWave and HunterHPQ15G-M2022-06-16Stop using it, sever the cord as the recall page shows, and contact Sienhua Group (North America) for a prorated refund.CPSC notice
WarmWave and HunterHPQ15G-M2022-06-16Stop using it and apply at homeproductservice.com/recall for a full or partial refund.Health Canada notice

Atomi

Stop using it, unplug it, and register at atomiheaterrecall.com for a full refund. Registration asks for photos of the cut cord and the label.

CPSC notice

Model numbers
  • AT1323
  • AT1481
  • AT1520
  • AT1632
  • AT1482
  • AT1521
  • AT1635

Atomi

Stop using it and register at atomiheaterrecall.com for a refund. Dispose of the heater under your municipality’s electronic waste rules.

Health Canada notice

Model numbers
  • AT1514
  • AT1513
  • AT1677

Cadet

Stop using it and contact Glen Dimplex for a free replacement and free installation by a qualified technician.

CPSC notice

Model numbers
  • HW128, HW132, HW151 (made 01-Mar-21 to 29-Feb-24)
  • HW162, HW162BP5, HW168, HW168BP5 (made before 01-Mar-24)

Danby

Stop using it and unplug it. Send Danby a photo of the cut cord for a full refund.

Health Canada notice

Model numbers
  • DBSH01113WD13, made June 2022

DEWALT

Stop using it and contact Enerco for new start instructions and a warning sticker. The remedy is a repair, not a refund.

CPSC notice

Model numbers
  • DXH70CFAVX

DEWALT

Stop using it and contact Enerco for new start instructions and a free warning sticker.

Health Canada notice

Model numbers
  • DXH70CFAVX
  • F340666

DREO

Stop using it and contact DREO for a free replacement. DREO asks for a photo of the heater with the cord cut.

CPSC notice

Model numbers
  • DR-HSH015, made 2025/04 to 2026/01

DREO

Stop using it and contact DREO for a free replacement heater.

Health Canada notice

Model numbers
  • DR-HSH015, made 2025/04 to 2026/01

Govee

Stop using it and use Govee’s recall page for a refund. A full refund needs the order number; without it the refund depends on the model.

CPSC notice

Model numbers
  • H7130
  • H7130101
  • H7131
  • H7132
  • H7133
  • H7134
  • H7135

Govee

Stop using it and register on Govee’s recall page for a refund.

Health Canada notice

Model numbers
  • H7130
  • H7130101
  • H7131
  • H7132
  • H7133
  • H7134
  • H7135

Home Easy

Stop using it and contact Home Easy for a full refund. The refund asks for a photo of the cut cord.

CPSC notice

Model numbers
  • DH-QN06

Konwin

Stop using it and return it to any Meijer store for a full refund to the original form of payment.

CPSC notice

Model numbers
  • BHN2133

Mastercraft

Stop using it and return it to the place of purchase for an exchange or a refund.

Health Canada notice

Model numbers
  • EH-4604BY, Mastercraft, date codes ending in 2020 or 2021
  • EH-4604BY, Thermosphere, date codes ending in 2020

Mastercraft

Stop using it and return it to the store where you bought it for a store credit or a replacement. No proof of purchase is needed.

Health Canada notice

Model numbers
  • HA22-48M and HA22-48M1 (Mastercraft, blue, any date)
  • HA22-48M (Profusion Heat, Prestige, Matrix, red, made June 2017 or earlier)

Merkury

Stop using it and return it to any HomeSense, Winners or Marshalls for a refund.

Health Canada notice

Model numbers
  • MIC-DHC02, as printed in the Health Canada notice

Merkury

Stop using it and contact Merkury Innovations for a full refund. The refund asks for a photo of the product with the cord cut.

CPSC notice

Model numbers
  • MI-DHC02

Shop LC

Stop using it and return it to Shop LC with the free prepaid label. The refund goes back to the original payment method.

CPSC notice

Model numbers
  • SKU 3666115
  • SKU 3666117
  • SKU 3666118
  • SKU 3666119

Shop LC

Stop using it and return it to Shop LC. The notice gives Shop LC’s toll-free number and email address.

Health Canada notice

Model numbers
  • SKU 3666115
  • SKU 3666117
  • SKU 3666118
  • SKU 3666119

Simnoble

Stop using it and dispose of it under your municipality’s electronic waste rules. The notice does not mention a refund.

Health Canada warning

Model numbers
  • Amazon.ca ASIN B0B7MQQQW9

Vornado

Stop using it and register on Vornado’s website for a full refund.

CPSC notice

Model numbers
  • TYPE SRTH with date code JUL22

Vornado

Stop using it and contact Vornado to confirm the unit. Included heaters get a free replacement.

CPSC notice

Model numbers
  • TYPE VH2 with date code JUL24 or AUG24

Vornado

Stop using it and contact Vornado for a full refund. The refund asks for photos and proof that the heater was destroyed.

CPSC notice

Model numbers
  • TYPE SRTH

Vornado

Stop using it and contact Vornado Air for a refund.

Health Canada notice

Model numbers
  • TYPE SRTH
  • Part number EH1-0084-06 (black)
  • Part number EH1-0084-43 (ice white)

WarmWave and Hunter

Stop using it, sever the cord as the recall page shows, and contact Sienhua Group (North America) for a prorated refund.

CPSC notice

Model numbers
  • HPQ15G-M

WarmWave and Hunter

Stop using it and apply at homeproductservice.com/recall for a full or partial refund.

Health Canada notice

Model numbers
  • HPQ15G-M

Shopping for a new one?

The heater cards already on the site are linked here. The recall line on a card is for that model only.

Questions

Which DREO heater is recalled?

The October 29, 2026 notices name model DR-HSH015, made from April 2025 through January 2026. The model number and the manufacture date, in YYYY/MM format, are printed on a label on the underside of the heater. A DREO heater with another model number is not named in those notices.

Which brands are on this list?

Atomi, Cadet, Danby, DEWALT, DREO, Govee, Home Easy, Konwin, Mastercraft, Merkury, Shop LC, Simnoble, Vornado, and WarmWave and Hunter. Some notices also name the seller or distributor, such as Glen Dimplex Americas for Cadet, Enerco for DEWALT, Meijer for Konwin, Sienhua Group for WarmWave and Hunter, and Canadian Tire for Mastercraft. A brand is here only because a CPSC or Health Canada notice names that product.

Does a notice for one heater cover every heater from that brand?

No. A notice covers the model numbers it names, and several cover only certain date codes. Vornado has four rows with different model lines and date limits. The CPSC and Health Canada notices for Atomi name different model numbers, and the Health Canada notice for Merkury prints MIC-DHC02 where the CPSC notice prints MI-DHC02. Read the row for the country where you bought the heater.

What is not on this list?

Patio heaters, fire pits, fireplaces, heated blankets and heating pads, hand warmers, and water heaters are other product types. Notices before 2022 are not in the table, and the older Lasko notices are on the Lasko page. The recall search covers CPSC and Health Canada notices since 2016.

Checked Lab catalogue

The site has five heater cards: the Lasko 32 inch CT32150, the Lasko Ready Heat 14 inch CT14401, the Dreo Atom 316, the Vornado AVH2 and the De’Longhi Dragon 4 TRD40615E. None of those model numbers is in the rows above. The DREO notices name DR-HSH015, not the Atom 316. The Vornado notices name TYPE SRTH and TYPE VH2, not the AVH2. No notice in the rows names a Lasko or De’Longhi heater.

All recall checks Black Friday Winter How we check Lasko space heater recall Air fryer recalls by brand Heated blanket recall list Levoit purifier model check Space heater label check eheat Envi wall heater recall KUL fan heater recall Seabreeze Smart Thermaflo bathroom heater fan recall Profusion Heat HA22-48M garage heater recall Vornado recalls Canadian Tire recalls DeWalt recalls

What the notices say

The longer text from each notice is below. The table at the top is the short version. Catalogue lines above use the 2026-11-25 (UTC) check.

CPSC · 2024-07-11

Atomi Recalls Smart Heaters Due to Fire and Burn Hazards

What the notice says

The CPSC notice, recall number 24-298, says this recall involves Atomi Smart Heaters, tower models AT1323, AT1481, AT1520 and AT1632; tabletop models AT1482 and AT1521; and wall heater model AT1635. It lists the units as about 99,400 (in addition, about 10,700 were sold in Canada). It says the firm has received one report of the heater turning on without user input. No injuries have been reported. It says they were sold at Amazon, Ace Hardware, Atomiusa.com, Best Buy, BJ’s Wholesale Club, Costco, Hammacher Schlemmer, Home Depot, Lowes.com, Menards, Sam’s Club and Walmart stores nationwide from October 2019 through April 2024.

Model numbers in the CPSC notice

  • AT1323
  • AT1481
  • AT1520
  • AT1632
  • AT1482
  • AT1521
  • AT1635

How to check your model

The notice says the model number is on a product identification sticker on the bottom of the unit. It lists AT1323, AT1481, AT1520 and AT1632 as tower models, AT1482 and AT1521 as tabletop models, and AT1635 as the wall model.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately, unplug them, and follow the instructions at atomiheaterrecall.com for a full refund. It says registration asks for a photo of the cut power cord and a photo of the manufacturer’s label on the underside.

Health Canada · 2024-07-11

Atomi Smart Heaters recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2024-07-11, identification 75576, says this recall involves the Atomi Smart Tabletop Heater, Tower Heater, and Wall Heater available in black, silver, and white colours. It says as of May 23, 2024, the company has received no reports of fire in Canada, and no reports of injuries. It says the company reported that 10,700 units of the affected products were sold in Canada and 99,400 were sold in the United States. It says the affected products were sold from October 2020 to April 2024.

Model numbers in the Health Canada notice

  • AT1514
  • AT1513
  • AT1677

How to check your model

The notice lists AT1514 as the tabletop heater, AT1513 as the tower heater and AT1677 as the wall heater, in black, silver and white. It does not say where the model number is printed. These model numbers are not the ones in the CPSC notice.

What the notice tells owners to do

The notice tells owners to stop using the heater immediately, register at atomiheaterrecall.com for a refund, and dispose of it under municipal electronic waste rules.

CPSC · 2024-09-12

Glen Dimplex Americas Recalls Cadet Apex72 Electric Heaters Due to Fire Hazard

What the notice says

The CPSC notice, recall number 24-360, says this recall involves Glen Dimplex Americas’ Cadet-branded Apex72 high wall electric heaters between 1200 and 1600 Watts. It says the fan-forced heaters have a white dust cover and are installed into walls a minimum of six feet off the ground. It says “Cadet,” the model number, and the manufacturing date in DD-MM-YY format appear on the rating label visible through the bottom of the air outlet grill. It lists the units as about 12,900. It says the firm has received one report of a heater fan malfunctioning and causing the unit to ignite. No injuries have been reported. It says they were sold through Platt, Crescent Electric, CED and other electrical distributors nationwide from February 2014 through February 2024.

Model numbers in the CPSC notice

  • HW128, HW132, HW151 (made 01-Mar-21 to 29-Feb-24)
  • HW162, HW162BP5, HW168, HW168BP5 (made before 01-Mar-24)

How to check your model

The notice says “Cadet,” the model number and the manufacturing date, in DD-MM-YY format, are on the rating label that shows through the bottom of the air outlet grill. It lists HW128, HW132 and HW151 made from 01-Mar-21 through 29-Feb-24, and HW162, HW162BP5, HW168 and HW168BP5 of any date before 01-Mar-24.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact Glen Dimplex for a free replacement heater and free installation. It says Glen Dimplex is working directly with apartment complexes and other living facilities, and that a qualified technician installs the replacement at no cost for owners who bought and installed a heater themselves.

Health Canada · 2023-08-01

Danby Space Heater 1500 Watt (11”) recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2023-08-01, identification 74004, says this recall involves the Danby 1500 Watt adjustable oscillating space heater. It says the recalled product is 11″ (28cm) in height and can be identified by model number DBSH01113WD13, UPC 067638030205, and the manufacturing date of June 2022. It says as of July 11, 2023 the company has received 2 reports of incidents, and no reports of injuries in Canada. It says the company reported that 154 units of the affected products were sold in Canada. It says the affected products were sold from November 2022 to March 2023.

Model numbers in the Health Canada notice

  • DBSH01113WD13, made June 2022

How to check your model

The notice says the model number is DBSH01113WD13, the UPC is 067638030205, and the manufacturing date is June 2022. It says the heater is 11 inches (28 cm) tall.

What the notice tells owners to do

The notice tells owners to stop using and unplug the heater. It says owners who send Danby a photo showing the cord has been cut receive a full refund.

CPSC · 2025-04-03

Enerco Recalls DEWALT 70,000 BTU Outdoor Portable Cordless Forced Air Propane Heaters Due to Fire and Burn Hazards; Sold Exclusively at Lowe's

What the notice says

The CPSC notice, recall number 25-203, says this recall involves DEWALT 70,000 BTU outdoor portable cordless forced air propane heaters model number DXH70CFAVX. It lists the units as about 21,250 (in addition, about 500 were sold in Canada). It says the firm has received 11 reports of overheating. No injuries have been reported. It says they were sold at Lowe’s stores nationwide and on Lowes.com from May 2024 through January 2025.

Model numbers in the CPSC notice

  • DXH70CFAVX

How to check your model

The notice says the model number DXH70CFAVX is on the hang tag, and “DEWALT” is printed in black on the side of the yellow lower part of the heater. It says the heaters are yellow and black.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact Enerco for new instructions and a warning sticker that describe how to start the heater with the power button. It says the instructions are also on Enerco’s website, and that Enerco and Lowe’s are contacting known purchasers directly.

Health Canada · 2025-04-03

DeWalt 70,000-BTU Outdoor Portable Cordless Forced Air Propane Heater recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2025-04-03, identification 77184, says this recall involves DEWALT® Model DXH70CFAVX 70,000-BTU Outdoor Portable Cordless Forced Air Propane Heater. It says as of March 7, 2025, the company has received two reports of the product overheating in Canada, and no reports of injuries. It says the company reported that 501 units of the affected products were sold in Canada and 21,256 were sold in the United States. It says the affected products were sold from May 2024 to January 2025.

Model numbers in the Health Canada notice

  • DXH70CFAVX
  • F340666

How to check your model

The notice says the model is DXH70CFAVX and lists a second model number, F340666, with the UPC 089301012424. It does not say where the model number is printed.

What the notice tells owners to do

The notice tells owners to stop using the heater immediately and contact Enerco for new supplemental instructions and a free warning sticker. It says they show how to start the heater with the power button so that the fan starts.

CPSC · 2026-10-29

DREO Recalls DR-HSH015 Space Heaters Due to Fire and Burn Hazards

What the notice says

The CPSC notice, recall number 27-054, says this recall involves DREO space heaters, model number DR-HSH015. It says the ceramic, electric heaters are black and measure about 11.5 inches wide and 13 inches tall and include a remote control. It says only units manufactured from April 2025 through January 2026 are included in this recall. It lists the units as about 338,800 (in addition, about 36,300 were sold in Canada). It says DREO has received 17 reports of space heaters igniting, three resulting in property damage and one in a burn injury to the hand. It says they were sold at Costco stores nationwide and online at Dreo.com, BestBuy.com, Kohls.com, Lowes.com, QVC.com, HomeDepot.com, B2BRenew.com and Costco.com from September 2025 through October 2026.

Model numbers in the CPSC notice

  • DR-HSH015, made 2025/04 to 2026/01

How to check your model

The notice says the model number and the manufacture date, in YYYY/MM format, are printed on a label on the underside of the heater, and “DREO” is on the front. It says only units made from April 2025 through January 2026 are included.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact DREO for a free replacement heater. It says owners are asked to unplug the heater, destroy it by cutting the electrical cord, and send a photo of the destroyed heater.

Health Canada · 2026-10-29

DREO Space Heaters recalled due to fire and burn hazards

What the notice says

The Health Canada notice, updated 2026-10-29, identification 82854, says this recall involves DREO portable oscillating ceramic space heaters in model number DR-HSH015. It says as of October 22, 2026, the company has received one reported incident and no reports of injury in Canada. It says the company reported that 36,288 units of the affected products were sold in Canada and 338,800 were sold in the United States. It says the affected products were sold from September 2025 to August 2026. It says the notice is a joint recall with the CPSC, that the black heaters measure about 29 cm wide by 33 cm tall, and that they include a remote control.

Model numbers in the Health Canada notice

  • DR-HSH015, made 2025/04 to 2026/01

How to check your model

The notice says the model number and the manufacture date are printed on labels on the underside of the heater, and the front is branded “DREO”. It says affected units were made from April 2025 (2025/04) to January 2026 (2026/01).

What the notice tells owners to do

The notice tells owners to stop using the heater immediately and contact DREO for a free replacement space heater.

CPSC · 2024-11-07

GoveeLife and Govee Smart Electric Space Heaters Recalled Due to Fire and Burn Hazards; Imported by Govee

What the notice says

The CPSC notice, recall number 25-036, says this recall involves GoveeLife and Govee smart electric space heaters with Model Numbers H7130 (including the H7130101 variation), H7131, H7132, H7133, H7134, and H7135. It says “GoveeLife” or “Govee” is printed on the front or side of each unit. It says the space heaters were sold in black and white and measure from 9 inches to 26 inches in height, depending on the model. It lists the units as about 512,500 (in addition, about 48,600 in Canada). It says the firms have received 113 reports of overheating, including seven reports of fires and one report of a minor burn injury. It says they were sold online at Amazon.com, us.govee.com, the Govee Home app and TikTok Shop from September 2021 through September 2024.

Model numbers in the CPSC notice

  • H7130
  • H7130101
  • H7131
  • H7132
  • H7133
  • H7134
  • H7135

How to check your model

The notice says “GoveeLife” or “Govee” is printed on the front or side, and the model number is on the manufacturer’s label on the underside of each unit.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact GoveeLife or Govee for a refund. It says owners unplug the heater, cut the power cord, and send an image of the destroyed heater, the manufacturer’s label and the serial number code through the firm’s recall page. It says an owner with the original order number gets a full refund, and an owner without it gets a refund that depends on the model.

Health Canada · 2024-11-07

GoveeLife and Govee Smart Electric Space Heaters recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2024-11-07, identification 76452, says this recall involves the GoveeLife and Govee smart electric space heaters with model numbers H7130 (including the H7130101 variation), H7131, H7132, H7133, H7134 and H7135. It says as of October 28, 2024, the company had received 7 reports of overheating in Canada and no report of injuries. It says approximately 48,584 units were sold in Canada, online through amazon.ca from October 2021 through May 2024. It says the notice is a joint recall with the CPSC.

Model numbers in the Health Canada notice

  • H7130
  • H7130101
  • H7131
  • H7132
  • H7133
  • H7134
  • H7135

How to check your model

The notice says the model number is on the manufacturer’s label on the underside of the unit, and “GoveeLife” or “Govee” is on the front or side.

What the notice tells owners to do

The notice tells owners to stop using the recalled heaters and register at the GoveeLife heater recall page for a refund.

CPSC · 2022-02-09

Home Easy Recalls Geek Heat Personal Heaters Due to Fire Hazard

What the notice says

The CPSC notice, recall number 22-077, says this recall involves the Home Easy Geek Heat DH-QN06 personal heaters. It lists the units as about 3,000. It says Home Easy has received three reports of the toggle power switch causing a fire. No injuries or property damage have been reported. It says they were sold at Army and Air Force Exchange Service stores, Value Zone stores in New Jersey, and online at amazon.com, walmart.com, target.com and wayfair.com from October 2020 through January 2021.

Model numbers in the CPSC notice

  • DH-QN06

How to check your model

The notice says the Geek Heat logo is printed on the top of the heater near the vent and the model number is printed on the underside. It says the heater is white and measures 20 inches long and 13 inches wide.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact Home Easy for a full refund. It says owners unplug the heater, cut the electrical cord, mark the product “defective” and dispose of it under local rules, then email a photo of the cut cord to Home Easy, and that Home Easy is contacting known purchasers directly.

CPSC · 2025-03-13

Meijer Recalls Konwin Desktop Heaters Due to Fire and Burn Hazards

What the notice says

The CPSC notice, recall number 25-179, says the recalled Konwin branded desktop heaters have model number BHN2133. It lists the units as about 6,050. It says the firm received eight reports of fans burning and melting. No injuries have been reported. It says they were sold at Meijer stores in Michigan, Ohio, Indiana, Illinois, Wisconsin and Kentucky from September 2024 through January 2025.

Model numbers in the CPSC notice

  • BHN2133

How to check your model

The notice says “Konwin” and the model number BHN2133 are printed on a label on the bottom of the heater. It says the heater has a white plastic frame, a black fan and black grill covers, and measures about 12 inches high and 10 inches wide.

What the notice tells owners to do

The notice tells owners to stop using the desktop heaters immediately and return them to any Meijer store for a full refund through the original form of payment.

Health Canada · 2023-05-05

Expanded Recall: Thermosphere and Mastercraft Ceiling-Mounted 7500W/240V Electric Utility Workshop/Garage Heater, Model EH-4604BY with Remote Control & Thermostat recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2023-05-05, identification 64127, says this recall expansion now includes Mastercraft model EH-4604BY products with date codes ending in 2021 (date codes ending in 2020 were included in the recall notice originally published on May 5, 2022). It says as of April 17, 2023, the companies have received 17 reports of incidents in Canada and no report of injuries. It says the company reported that approximately 9,699 units of the affected product were sold in Canada. It says the affected products were sold from August 2020 to April 2023.

Model numbers in the Health Canada notice

  • EH-4604BY, Mastercraft, date codes ending in 2020 or 2021
  • EH-4604BY, Thermosphere, date codes ending in 2020

How to check your model

The notice says the model number EH-4604BY and the cETL number 4003667 are on the rating label, with the date code in MM/YYYY format. It lists Mastercraft heaters sold at Canadian Tire, SKU 043-5120-2, with date codes ending in 2020 or 2021, and Thermosphere heaters sold at Canac, SKU 4041041, with date codes ending in 2020. It says Mastercraft units also have a date code sticker in DDMMYY format on the box and on the product, and that codes ending in 20 or 21 are included.

What the notice tells owners to do

The notice tells owners to stop using the heater and return it to the place of purchase for an exchange or a refund.

Health Canada · 2023-08-24

Mastercraft, Profusion Heat, Prestige, and Matrix Portable Garage Heaters recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2023-08-24, identification 74165, says this recall involves the Mastercraft, Profusion Heat, Prestige and Matrix 4800 W 240 V portable garage heaters, which carry Intertek (ETL) certification file number 3153457. It says that as of August 17, 2023, H.E. Industrial Ltd. had received 10 reports of overheating in Canada, including 3 incidents of the heater catching fire and damaging property, and that no injuries were reported. It says the company reported 68,000 units sold in Canada from July 2014 to April 2019, at Canadian Tire and various other retailers.

Model numbers in the Health Canada notice

  • HA22-48M and HA22-48M1 (Mastercraft, blue, any date)
  • HA22-48M (Profusion Heat, Prestige, Matrix, red, made June 2017 or earlier)

How to check your model

The notice says the model number, the Intertek (ETL) certification file number 3153457 and the manufacturing date, in MM-YY format, are on the label on the back of the heater. It lists the blue Mastercraft heaters with models HA22-48M and HA22-48M1 of any date, and the red Profusion Heat, Prestige and Matrix heaters with model HA22-48M made June 2017 (06-17) or earlier.

What the notice tells owners to do

The notice tells owners to stop using the heater immediately and return it to the place of purchase for a store credit or a replacement unit. It says proof of purchase is not required.

Health Canada · 2026-04-29

Merkury Innovations Hot + Cool Heating and Cooling Fan recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2026-04-29, identification 81984, says this recall involves the Merkury Innovations Hot + Cold Heating and Cooling Fan with model number MIC-DHC02. It says as of April 20, 2026, the company has received 2 reports of the fan catching fire when connecting to a power source in Canada, and no reports of injuries. It says the company reported that 1,800 units of the affected products were sold in Canada. It says the affected products were sold from June 2025 to October 2025.

Model numbers in the Health Canada notice

  • MIC-DHC02, as printed in the Health Canada notice

How to check your model

The notice prints the model number as MIC-DHC02, with a C, where the CPSC notice prints MI-DHC02. It says the model number is on a label on the bottom of the product and on the packaging.

What the notice tells owners to do

The notice tells owners to stop using the recalled products immediately and return them to any HomeSense, Winners or Marshalls for a refund.

CPSC · 2026-06-11

Merkury Innovations Recalls Hot + Cool Heating and Cooling Fans Due to Risk of Serious Injury or Death from Fire Hazard

What the notice says

The CPSC notice, recall number 26-539, says this recall involves the Merkury Innovations Hot + Cool Heating and Cooling Fan, a portable hot-and-cool bladeless fan and heater with model number MI-DHC02. It lists the units as about 18,000. It says the firm has received two reports of the fan catching fire when connected to a power source, including one report of smoke damage to property. No injuries have been reported. It says they were sold at TJMaxx, Marshalls and Sierra stores nationwide from October 2024 through October 2025.

Model numbers in the CPSC notice

  • MI-DHC02

How to check your model

The notice says the model number MI-DHC02 is on a white label on the bottom of the product and on the packaging. It describes a portable bladeless fan and heater about 13 inches tall, 5 inches wide and 5 inches deep, weighing about 2 pounds.

What the notice tells owners to do

The notice tells owners to stop using the fan immediately and contact Merkury Innovations for a full refund. It says owners write the date, their initials and the word “Recalled” on the product in permanent marker, unplug it, cut the cord, and upload a photo of the destroyed product to the firm’s recall page, and that disposal instructions follow once registration is confirmed.

CPSC · 2022-02-10

Shop LC Recalls Electric Space Heaters Due to Fire and Burn Hazards (Recall Alert)

What the notice says

The CPSC notice, recall number 22-723, says this recall involves Shop LC personal electric space heaters. It says the heaters are black or white with a gold grill and were sold individually or in sets of two. It says the heaters sold individually have a dome-shaped top and a carrying handle. It lists the units as about 4,500. It says Shop LC has received two reports of the electric heaters overheating. No injuries have been reported. It says they were sold on Shop LC television networks and online at shoplc.com from December 2020 through February 2021.

SKU numbers in the CPSC notice

  • SKU 3666115
  • SKU 3666117
  • SKU 3666118
  • SKU 3666119

How to check your model

The notice says the SKU numbers are not printed on the product. It lists 3666115 as a set of two black heaters, 3666117 as a set of two white heaters, 3666118 as a single white heater and 3666119 as a single black heater, each 110 V and 400 W.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and return them to Shop LC. It says Shop LC is notifying known purchasers directly and sending free return labels with prepaid postage, and that the refund goes back through the original method of payment once the heaters arrive.

Health Canada · 2022-06-16

Shop LC Personal Electric Space Heaters recalled due to Fire and Burn Hazard

What the notice says

The Health Canada notice, updated 2022-06-16, identification 64272, says this recall involves Shop LC Personal Electric Space Heaters. It says as of April 22, 2022, the company has received no reports of incidents or injuries in Canada. It says the company reported that 2 units of the affected product were sold in Canada. It says the affected products were sold from December 2020 to February 2021.

SKU numbers in the Health Canada notice

  • SKU 3666115
  • SKU 3666117
  • SKU 3666118
  • SKU 3666119

How to check your model

The notice says the SKU numbers are not printed on the product. It lists 3666115 as a set of two black heaters, 3666117 as a set of two white heaters, 3666118 as a single white heater and 3666119 as a single black heater, each 110 V and 400 W.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and return them to Shop LC. It gives Shop LC’s toll-free number and email address for more information.

Health Canada warning · 2024-11-28

Health Canada warns that the Simnoble 2 in 1 Mini Ceramic Space Heater with Humidifier available on Amazon.ca may pose a risk of fire

What the notice says

The Health Canada notice, published 2024-11-28, identification 76573, is an advisory about one product. It says the product was sold as a tabletop heater and humidifier unit on Amazon.ca under the ASIN B0B7MQQQW9. It says Amazon.ca reported 852 units sold in Canada between July 2022 and September 2023, and that Health Canada contacted the foreign third-party seller. It says one fire involving the product was reported to Health Canada, with no injuries.

Identifier in the Health Canada notice

  • Amazon.ca ASIN B0B7MQQQW9

How to check your model

The notice names no model number. It says the product was sold on Amazon.ca as a tabletop heater and humidifier under the ASIN B0B7MQQQW9, and describes a corded, white, cylindrical ceramic heater with a water reservoir on top, 21.2 cm tall and 13.5 cm across.

What the notice tells owners to do

The notice tells owners to stop using the product immediately and dispose of it under their municipality’s electronic waste rules. It says the product was removed from sale on Amazon.ca. It mentions no refund.

CPSC · 2023-03-09

Vornado Air Recalls Portable SRTH Small Room Tower Heaters Due to Fire Hazard

What the notice says

The CPSC notice, recall number 23-148, says this recall involves Vornado SRTH Small Room Tower Heaters with a “JUL22” date code and “TYPE SRTH” printed on the silver rating label located on the underside of the product. It says the electric space heaters are black and measure about 12.5 inches high by 6 inches wide by 6 inches in diameter and have two heat settings (low and high) and a fan only/no heat setting. It says “Vornado” with a red “V” behind it is located on the front of the unit. It lists the units as about 1,450. It lists no reports of incidents or injuries. It says they were sold at Bed Bath & Beyond and other stores nationwide, and online at Amazon.com and other websites, from November 2022 through December 2022.

Model numbers in the CPSC notice

  • TYPE SRTH with date code JUL22

How to check your model

The notice says TYPE SRTH is on the silver rating label on the underside and only units with the date code JUL22 are included. It says the date code is the first five digits of the serial number on that label.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and register on Vornado’s website for a full refund.

CPSC · 2025-01-16

Vornado Air Recalls VH2 Whole Room Heaters Due to Electric Shock and Fire Hazards; Sold Exclusively on Amazon.com

What the notice says

The CPSC notice, recall number 25-093, says the recall involves Vornado VH2 Whole Room Heaters with a “JUL24” or “AUG24” date code and “TYPE VH2” printed on the silver rating label on the underside of the heater. It says the heaters are off white and have thermostatic temperature control, automatic or continuous fan operation and two heat settings. It says “Vornado” with a red “V” behind it is printed on the front of the unit. It lists the units as about 7,780. It lists no reports of incidents or injuries. It says they were sold online at Amazon.com from August 2024 through October 2024.

Model numbers in the CPSC notice

  • TYPE VH2 with date code JUL24 or AUG24

How to check your model

The notice says TYPE VH2 and the date code JUL24 or AUG24 are printed on the silver rating label on the underside. It says only units with one of those two date codes are included.

What the notice tells owners to do

The notice tells owners to stop using the recalled heaters immediately and contact Vornado to confirm the unit is included and to receive instructions for a free replacement heater.

CPSC · 2026-06-04

Vornado Air Recalls SRTH Small Room Tower Heaters Due to Fire Hazard

What the notice says

The CPSC notice, recall number 26-532, says the recalled Vornado SRTH small room tower heaters were sold in black and white and measure about 12.5 inches high by 6 inches in diameter. It says the recalled heaters have two heat settings (low and high) and a fan only/no heat setting. It says the word “Vornado” with a “V” behind it is printed on the front of the unit. It lists the units as about 255,000 (in addition, about eight were sold in Canada). It says Vornado has received 32 reports of overheating from fan displacement, including eight reports of fire and one report of smoke inhalation. It says they were sold at stores nationwide, including Kohl’s, Bed Bath & Beyond and ACE Hardware, and online at Vornado.com and Amazon.com, from August 2013 through May 2026.

Model numbers in the CPSC notice

  • TYPE SRTH

How to check your model

The notice says TYPE SRTH is printed on the silver rating label on the bottom of the heater, and the word “Vornado” with a “V” behind it is on the front. It gives no date-code limit.

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and contact Vornado for instructions on submitting photos of the product and proof of destruction to receive a full refund.

Health Canada · 2026-06-04

Vornado SRTH Small Room Tower Heater recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2026-06-04, identification 82149, says this recall involves Vornado SRTH Small Room Tower Heater. It says this product was produced between 2013 and 2022. It says as of May 25, 2026, the company has received no reports of incident or injury in Canada. It says the company reported that 8 units of the affected products were distributed in Canada and 212,000 were sold in the United States. It says the affected products were sold from January 2013 to May 2026.

Model numbers in the Health Canada notice

  • TYPE SRTH
  • Part number EH1-0084-06 (black)
  • Part number EH1-0084-43 (ice white)

How to check your model

The notice says TYPE SRTH is printed on the silver rating label on the bottom of the product, and “Vornado” with a “V” behind it is on the front. It lists part number EH1-0084-06, UPC 043765008478, for the black heater and EH1-0084-43, UPC 043765009390, for the ice white heater.

What the notice tells owners to do

The notice tells owners to stop using the recalled product immediately and contact Vornado Air for a refund.

CPSC · 2022-06-16

Sienhua Group Recalls WarmWave and Hunter Ceramic Tower Heaters Due to Fire and Burn Hazards

What the notice says

The CPSC notice, recall number 22-168, says this recall involves WarmWave and Hunter 18 inch 1,500-Watt Oscillating Ceramic Tower Heaters, under license to Sienhua Group (North America). It lists the units as about 580,000 (in addition, about 37,580 in Canada). It says the firm has received eight customer reports of fire at the plug or cord and dozens of customer reports of the plug or cord overheating. There have been no reports of injury or death and one report of minor property damage. It says they were sold at Home Depot stores nationwide and online at Amazon.com, eBay and other websites from September 2013 through February 2022.

Model numbers in the CPSC notice

  • HPQ15G-M

How to check your model

The notice says the model number HPQ15G-M is on the silver ETL label on the bottom of the heater. It says the heaters are black and 18 inches tall, with an automatic shutoff and two heat settings, and are sold under license to Sienhua Group (North America).

What the notice tells owners to do

The notice tells owners to stop using the heaters immediately and unplug the unit. It says to follow the instructions at homeproductservice.com/recall on severing the cord so the unit cannot be used, and to contact the distributor, Sienhua Group (North America), for a prorated refund.

Health Canada · 2022-06-16

WarmWave and Hunter Oscillating Ceramic Tower Heaters recalled due to fire hazard

What the notice says

The Health Canada notice, updated 2022-06-16, identification 64269, says this recall involves WarmWave and Hunter Oscillating Ceramic Tower Heaters. It says as of June 13, 2022, the company has received no reports of injuries or incidents in Canada. It says the company reported that 14,764 units of the WarmWave product and 22,816 units of the Hunter product were sold in Canada. In the United States, approximately 580,000 units were sold in total. It says the affected products were sold from September 2013 to January 2020.

Model numbers in the Health Canada notice

  • HPQ15G-M

How to check your model

The notice says the model number HPQ15G-M is on the cETL label on the bottom of the product.

What the notice tells owners to do

The notice tells owners to stop using the recalled product immediately and visit homeproductservice.com/recall to apply for a full or partial refund.